VRF Active

Minimum length – maximum accuracy.

The VRFactive volume flow controllers are used to control a constant or variable volume flow in rectangular air ducts of Comfort Air Technology systems, up to full shut-off, regardless of the inlet pressure. Available with dynamic (VRFactive) and static (VRFactive-s) measuring principle. Activation and control are carried out with external energy (electrical).
The housing cross-sections match the recommended edge lengths for rectangular air ducts in accordance with DIN EN 1505. This makes it possible to select the largest possible flow cross-section even in cramped installation conditions.
The housing has flanges with slotted holes, with cage nuts for the insulated version.

  • Highest control accuracy of all known controllers in the low air velocity range due to differential pressure amplification
  • Energy-efficient – minimal pressure loss due to small differential pressure element
  • Very short design, insensitive to inflow, simple integration
  • Optimized construction with particularly high airtightness
  • Also with static differential pressure measurement – suitable for laboratories and hospital

Powerful effect: LTG ActiveControl map measurement

  • Highest measuring accuracy of all known systems in the low air velocity range.
  • Combines extremely short installation lengths with maximum control accuracy in the low air velocity range
  • Insensitive to incident flow due to optimized air routing to the measuring element
  • Max. 5 % deviation for Vnenn

Ready for a breath of fresh air? Contact our comfort air experts now and breathe easy – literally!

Technical data

Technical Data for L_pa= 35 dB(A)

Volumenstrombereich 17 - approx. 17 Volumenstrombereich 300 m³/h Regelverhältnis 10 : 1 Differenzdruckbereich up to 1000 Pa Gehäuseleckage nach DIN EN 1751 Class C Luftdichte Absperrung nach DIN EN 1751 Class 4 (200 x 100: Class 3) Regelabweichung max. 5% from V

Dimensions (Length x Width x Height in mm)

200 x 100-1200 x 400 Installation length [mm] 135 - 420

Design/Options

Housing version analog Galvanized steel MP (optional) coated BACnet Silencer SDE (optional) Modbus Messprinzip dynamisch (für nicht belastete Luft) Static (for polluted air) (optional) Stainless steel (optional) Handeinstellgerät (optional) Insulating shell (optional) Analog / digital control (bus)

Downloads

Specification text Variable volumetric flow controller VRFactive
DOC 45.35 kB
Ordering help for variable volume flow controllers
FILE 217.52 kB
Operating instructions 4-stage switch for domestic ventilation
PDF 597.96 kB
Planning aid for volume flow control
PDF 367.24 kB
Newsletter NFC "Assistant App"
PDF 393.18 kB
Short information air distribution unit VR Active
PDF 885.64 kB
Installation Instructions variable flow rate controllers VR. active
PDF 1.43 MB
Presentation Air Distribution Unit VR active
PDF 431.17 kB
Technical brochure air distribution unit VRF Active
PDF 1.34 MB
Dimension tool volume flow controller VRE active / VRF active
XLS 4.58 MB

Impressions

Innovations