Wind tunnel Fahrtwind-Simulators VAF

The LTG Fahrtwind-Simulators have been specially developed for use in test benches in the automotive industry, test laboratories in mechanical and plant engineering and by certifying organizations such as TÜV. However, they can also be used universally for other cooling or inflow simulations to ensure quality assurance in development, service and final inspection.

Our convenient operating concepts and integration options make an additional contribution to this. LTG Fahrtwind-Simulators are characterized by the use of LTG axial/radial fans with the following advantages:

  • High efficiency of up to 89 %
  • Low-noise due to streamlined impeller and housing contour
  • Optimum aerodynamic properties

Ready for a breath of fresh air? Contact our process air experts now and breathe easy – literally!

Technical data

TypeAverage blow-out speed [km/h]Blow-out cross section HxW [mm]Blow-out height above the bottom [mm]Conveyed volume flow [m³/h]Ambient temperature [°C]Requirement
VRSF 1120 E403096 (60 mph)1 000 x 1 700150 - 450163 200-40 to +50SCO3, CFR
137 (85 mph)800 x 1000200 - 500109 600-40 to +50CFR
145 (90 mph)800 x 1000200 - 500160 000-40 to +50CFR
135600 x 1000200 - 50081 000-40 to +50WLTP
VRSF 1120 E39611601 000 x 80050128 000-10 to +45RDE, WLTP
VAF 2x1120 E400496 (60 mph)1 000 x 1 700 150163 200+10 to +40SC03, CFR
VAF 2500 E39341801 100 x 2 000200 - 500 400 0000 to +40
VAF 2240 E3949/E39041601 000 x 2 000200 - 500 320 0000 to +40
VAF 2240 E37941451 800 x 1 050100270 000-10 to +40
VAF 2240 E38471451 000 x 2 000 360° rotatable290 000-10 to +40
VAF 1400100715 x 1 400125100 000+10 to +40